[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) ::
جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains
چکیده:   (2011 مشاهده)
Objective: An ideal orthodontic force system should exert continuous light force. Thus, many efforts have been made to improve the memory characteristics of elastomeric chains. The aim of this study was to compare elastomeric chains (ECs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams.
Materials and Methods: In this in-vitro study, ECs were divided into six groups, each containing 40 pieces of chain, from three brands (American Orthodontics, GAC and Ortho-Technology). Each brand was divided into two groups with respect to their claimed characteristics (with or without memory). Each sample was stretched to twice its original length and kept constant in 37°C distilled water. Force-extension diagrams were drawn by universal testing machine at 0,1,8,24,72 hours and 1, 2, 4-week intervals. Additionally, the amounts of elongation required to deliver 200 g force were calculated. To compare the results, ANOVA and Tukey tests were performed.
Results: Force-decay rate was significantly different between traditional and memory chains (p<0.05). For traditional chains, there was a substantial decay in force in the first hour and 30-40% of the force was retained at 4 weeeks. The memory chains demonstrated more constant force and retained 60% of the force. The maximum amount of elongation required to deliver 200 g force belonged to American Orthodontics memory chains (61.9% after 24hr) and the minimum to Ortho-Technology ECs (23.4% initially). 
  Conclusion: Memory chains exhibited superior mechanical properties compared to traditional ones. For delivering the same force, memory chains required more elongation. Memory chains of GAC and American Orthodontics showed better characteristics among all chains.

Source: Journal of Dentistry of Tehran University of Medical Sciences

Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1391/11/12 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mirhashemi A, Saffarshahroudi A, Sodagar A, Atai M. Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-974-fa.html

Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-974-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4710