[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 1, Issue 1 And 1 (1-2012) ::
3 2012, 1(1 And 1): 0-0 Back to browse issues page
Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains
AH. Mirhashemi , A. Saffarshahroudi , A. Sodagar * , M. Atai
Dental Research Center, Department of Orthodontics, Faculty of Dentistry, Tehran University of Medical Sciences
Abstract:   (2019 Views)
Objective: An ideal orthodontic force system should exert continuous light force. Thus, many efforts have been made to improve the memory characteristics of elastomeric chains. The aim of this study was to compare elastomeric chains (ECs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams.
Materials and Methods: In this in-vitro study, ECs were divided into six groups, each containing 40 pieces of chain, from three brands (American Orthodontics, GAC and Ortho-Technology). Each brand was divided into two groups with respect to their claimed characteristics (with or without memory). Each sample was stretched to twice its original length and kept constant in 37°C distilled water. Force-extension diagrams were drawn by universal testing machine at 0,1,8,24,72 hours and 1, 2, 4-week intervals. Additionally, the amounts of elongation required to deliver 200 g force were calculated. To compare the results, ANOVA and Tukey tests were performed.
Results: Force-decay rate was significantly different between traditional and memory chains (p<0.05). For traditional chains, there was a substantial decay in force in the first hour and 30-40% of the force was retained at 4 weeeks. The memory chains demonstrated more constant force and retained 60% of the force. The maximum amount of elongation required to deliver 200 g force belonged to American Orthodontics memory chains (61.9% after 24hr) and the minimum to Ortho-Technology ECs (23.4% initially). 
  Conclusion: Memory chains exhibited superior mechanical properties compared to traditional ones. For delivering the same force, memory chains required more elongation. Memory chains of GAC and American Orthodontics showed better characteristics among all chains.

Source: Journal of Dentistry of Tehran University of Medical Sciences

Full Text

Keywords: Elastomeric, Orthodontic Appliance Design
     
Type of Study: Research | Subject: Orthodontics
Received: 2013/01/31 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mirhashemi A, Saffarshahroudi A, Sodagar A, Atai M. Force-Degradation Pattern of Six Different Orthodontic Elastomeric Chains. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-974-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 1, Issue 1 And 1 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.08 seconds with 36 queries by YEKTAWEB 4712