Comparison of microleakage and thickness of resin cement in ceramic inlays with various temperatures
چکیده:   (1537 مشاهده)
Background and aims. Microleakage is still one of the major problems of composite-based restorations. This study compared the microleakage and thickness of resin cement in ceramic inlays with various temperatures. 
Materials and methods. Class V cavities were prepared on the buccal and lingual aspects of thirty human molars with occlusal margins in enamel and gingival margins in dentin (3 mm wide, 5 mm long and 2 mm deep). Laboratory-made inlays (LMI) were used for buccal cavities, and CAD/CAM inlays (CMI) were used for lingual cavities. All the cavities were divided into six groups (n=10): 1) LMI at -5°C 2) LMI at 50°C 3) LMI at room temperature (25°C) 4) CMI at -5°C 5) CMI at 50°C 6) CMI at room temperature (25°C). Inlays were bonded to cavities in a pulp pressure- and temperature-simulating device. After thermocycling and dye penetration, the teeth were divided into two mesiodistal halves. Amount of dye penetration and film thickness were measured under a stereomicroscope and analyzed with Kruskal-Wallis, Wilcoxon and Spearman's correlation tests (ɑ = 0.05). 
Results. There were no statistically significant differences in leakage between different inlay temperatures (P > 0.05). The mean cement thickness in laboratory-made inlays (gingival margin, 83.7 ± 11 and occlusal margin, 84.7 ± 19) was greater than that in CAD/CAM inlays (gingival margin, 69 ± 16 and occlusal margin, 84.7 ± 16). No correlation was found between cement thickness and microleakage either in enamel or dentin for any of the ceramic systems.
Conclusion. Differences in inlay temperature had no effect on microleakage. CAD/CAM inlays had lower cement thickness than laboratory-made inlays, but this was not related to their microleakage.

Source: Journal of Dental Research, Dental Clinics, Dental Prospects

Full Text

واژه‌های کلیدی: microleakage، film thickness، ceramic، CAD-CAM
     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1394/6/21 | پذیرش: 1394/6/21 | انتشار: 1394/6/21
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Comparison of microleakage and thickness of resin cement in ceramic inlays with various temperatures. 1. 1390;

URL: http://idai.ir/article-1-3291-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.04 seconds with 37 queries by YEKTAWEB 4710