| Comparison of microleakage and thickness of resin cement in ceramic inlays with various temperatures | 
								
								  |  | 
								
								  |  | 
								
								  |  | 
                                
								  | چکیده:       (1798 مشاهده) | 
								
								  | Background and aims. Microleakage is still one of the major problems of composite-based restorations. This study compared the microleakage and thickness of resin cement in ceramic inlays with various temperatures. Materials and methods. Class V cavities were prepared on the buccal and lingual aspects of thirty human molars with occlusal margins in enamel and gingival margins in dentin (3 mm wide, 5 mm long and 2 mm deep). Laboratory-made inlays (LMI) were used for buccal cavities, and CAD/CAM inlays (CMI) were used for lingual cavities. All the cavities were divided into six groups (n=10): 1) LMI at -5°C 2) LMI at 50°C 3) LMI at room temperature (25°C) 4) CMI at -5°C 5) CMI at 50°C 6) CMI at room temperature (25°C). Inlays were bonded to cavities in a pulp pressure- and temperature-simulating device. After thermocycling and dye penetration, the teeth were divided into two mesiodistal halves. Amount of dye penetration and film thickness were measured under a stereomicroscope and analyzed with Kruskal-Wallis, Wilcoxon and Spearman's correlation tests (ɑ = 0.05).  Results. There were no statistically significant differences in leakage between different inlay temperatures (P > 0.05). The mean cement thickness in laboratory-made inlays (gingival margin, 83.7 ± 11 and occlusal margin, 84.7 ± 19) was greater than that in CAD/CAM inlays (gingival margin, 69 ± 16 and occlusal margin, 84.7 ± 16). No correlation was found between cement thickness and microleakage either in enamel or dentin for any of the ceramic systems. 
Conclusion. Differences in inlay temperature had no effect on microleakage. CAD/CAM inlays had lower cement thickness than laboratory-made inlays, but this was not related to their microleakage. 
 Source:
Journal of Dental Research, Dental Clinics, Dental Prospects  Full
Text | 
								
								  |  | 
								
								  | واژههای کلیدی:  microleakage، film thickness، ceramic، CAD-CAM | 
								
								  |  | 
								
								  |  | 
								
								  | نوع مطالعه:  پژوهشي |
                                  موضوع مقاله: 
                                  ترمیمی دریافت: 1394/6/21 | پذیرش: 1394/6/21 | انتشار: 1394/6/21
 | 
                                
                                  
                                    |  | 
								
								  |  | 
								
								  |  | 
								
								  |  | 
								
								  | ارسال نظر درباره این مقاله | 
                                
                                |  | 
								
								  |  |