[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) ::
جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
The reliability of assessing rotation of teeth on photographed study casts
چکیده:   (2031 مشاهده)

 Objective: To examine the intra- and interexaminer reliability of assessing rotation of teeth on photographed study casts. In addition, the reliability parameters of two examiners scoring in mutual consultation were compared with the reliability parameters by one observer.

 Materials and Methods: Standardized photographs of sets of maxillary and mandibular plaster casts of 10 patients before treatment (T1), after treatment (T2), and a long time after retention (T3) were digitized. Tooth rotation was assessed relative to a correct position in the ideal dental arch form. A computer analysis program was used to process the measurements. Two examiners assessed each study cast twice with a washout period of 3 weeks. A third examiner assessed each cast, together with one of the other examiners. The intra- and interexaminer agreements were calculated using intraclass correlation coefficients (ICCs). Wilcoxon signed-rank tests were used to determine significant differences between the intra- and interexaminer reliability coefficients of the three examiners.

 Results: The ICCs ranged from 0.430 to 0.991. Incisors showed the highest ICCs and molars showed the lowest ICCs. Intraexaminer ICCs of the experienced examiners were significantly higher than those of the examiner with less experience. No significant differences in the reliability between a single examiner and the combination of two examiners were found.

  Conclusion: The method of assessing tooth rotation in the present study has proved to be reproducible, except for the molars. This method can be helpful for clinicians assessing tooth rotation from photographed study casts.


 Source: Angle Orthodontists

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1391/9/21 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

M. J. Vermeulen F, H. A. Aartman I, Kuitert R, Zentner A. The reliability of assessing rotation of teeth on photographed study casts. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-807-fa.html

The reliability of assessing rotation of teeth on photographed study casts. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-807-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 35 queries by YEKTAWEB 4710