An in vitro study of factors affecting the primary stability of orthodontic mini-implants
چکیده:   (2277 مشاهده)

 Objectives: To evaluate the effects of mini-implant features (length, design, core diameter), insertion technique (insertion angle, cortical punch), and cortical bone depth and density on mini-implant primary stability. The effect of mini-implant reinsertion was also investigated.

 Materials and Methods: Two hundred and sixty Infinitas mini-implants of two lengths (9 mm and 6 mm), two core diameters (0.8 mm and 0.9 mm) for an external diameter of 1.5 mm, and four designs (two tapered, external diameter 1.5 mm two cylindrical, external diameters 1.5 mm and 2.0 mm) were inserted into synthetic bone blocks, and the maximum insertion torque (MIT) was recorded. The cortical layer of the blocks varied in density (30 and 50 lb per cubic foot) and depth (1 mm and 2 mm). Three angles of insertion (90°, 75°, and 60°) and two methods of insertion (direct and cortical punch) were tested. Forty mini-implants were also removed and reinserted.

 Results: A significant increase in the average MIT occurred when cortical bone density increased and when mini-implants were reinserted. The 1.5 mm diameter cylindrical design had significantly lower MIT than the 1.5 mm tapered and the 2.0 mm cylindrical designs. The other variables did not have a significant effect on MIT.

 Conclusions: Mini-implants achieved greater primary stability in higher-density cortical bone, and the 1.5 mm diameter tapered and 2.0 mm cylindrical designs offered greater primary stability than the 1.5 mm cylindrical design. Reinserting mini-implants resulted in significantly increased MIT, possibly because of blunting of the threads.


 Source: Angle Orthodontists

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1391/9/20 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Holm L, J. Cunningham S, Petrie A, R. J. Cousley R. An in vitro study of factors affecting the primary stability of orthodontic mini-implants. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-805-fa.html

An in vitro study of factors affecting the primary stability of orthodontic mini-implants. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-805-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4710