Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography
چکیده:   (2607 مشاهده)

 Introduction The aims of this study were to determine the accuracy of volumetric measurements of teeth in vitro by cone-beam computed tomography (CBCT) and to analyze the factors affecting their volume measurements from the CBCT data.

 Methods We used a sample of CBCT-scanned (voxel sizes: 0.125, 0.20, 0.25, 0.30, and 0.40 mm) and laser-scanned crowns (n = 40) and roots (n = 32). The Tukey test was used to assess the differences between the CBCT-scan and the laser-scan volumes.

 Results There was a statistically significant difference between the laser-scan crown volume and each voxel size of CBCT-scan crown volume (P <0.05). CBCT-scan crown volumes at 0.30 and 0.40 mm were statistically significantly distinct from those at 0.125, 0.20, and 0.25 mm (P <0.05). There was a statistically significant difference between the laser-scan root volume and each voxel size of CBCT-scan root volume (P <0.05). The laser-scan root volume at 0.40 mm was statistically significantly distinct from the volumes at 0.125 and 0.20 mm (P <0.05). The in-vitro volume measurements from the CBCT scans were larger than those of the laser scans: from 21.73% to 43.92% in the crown halves, and from 18.27% to 41.58% in the root halves at the different voxel sizes.

 Conclusions With increasing voxel sizes during scanning, the volume measurements of teeth tended to be larger. The surface surrounding artifacts might lead to larger volumes.


 Source: Journal of Orthodontics and Dentofacial Orthopedics

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1391/9/13 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ye N, Jian F, Xue J, Wang S, Liao L, Huang W, et al . Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-787-fa.html

Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-787-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.07 seconds with 37 queries by YEKTAWEB 4710