[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 2, Issue 2 (1-2012) ::
3 2012, 2(2): 0-0 Back to browse issues page
Comparison of two canal preparation techniques using Mtwo rotary instruments
Faeze Hamze * , Kiamars Honardar , Kiumars Nazari Moghadam
Kerman University of Medical Sciences, Kerman, Iran
Abstract:   (3233 Views)

  INTRODUCTION: Root canal preparation is an important process in endodontic therapy. Nickel-titanium (NiTi) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. The purpose of this in vitro study was to compare single length with crown-down methods’ shaping ability using Mtwo NiTi files.

  MATERIALS & METHODS: Fifteen acrylic-resin blocks containing simulated canals were divided into two experimental groups. In group A, single length technique was used and in group B root canals were prepared by crown-down technique. Pre- and post-preparation canals were photographed in a standardized manner and were superimposed. The inner and outer walls of canal curvature were evaluated at three points (apical, middle and coronal) to determine the greatest change. The data was statistically analyzed using the Student t-test by Statistical Analysis System (SAS) software.

  RESULTS: Statistical analysis revealed that in group B, dentine was equally removed within the canal coronal to the curvature, whereas in group A, the inner wall was predominantly removed (P < 0.01). The two groups had no significant difference at the apical and middle points of the canal curvature.

  CONCLUSION: Our in vitro study revealed no significant difference between the single length method and crown-down technique using Mtwo for preparation of apical and middle portion of canal curvature.


  Source: Iranian Endodontic Journal

  Full text

Keywords: Curvatures, Instrumentation, Nickel-Titanium, Root canal preparation.
     
Type of Study: Research | Subject: Endodontics
Received: 2012/05/2 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Hamze F, Honardar K, Nazari Moghadam K. Comparison of two canal preparation techniques using Mtwo rotary instruments. 3 2012; 2 (2)
URL: http://idai.ir/article-1-486-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 2, Issue 2 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 36 queries by YEKTAWEB 4714