[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 6، شماره 6 - ( پریودنتولوژی 1390 ) ::
جلد 6 شماره 6 صفحات 0-0 برگشت به فهرست نسخه ها
The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis
چکیده:   (1551 مشاهده)
Background: The aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. 
  Materials and Methods: Replace select tapered and Branemark MK III implants were selected. Each of these two selected groups was divided into nine subgroups based on the implant length (IL) (short, medium and long) and the implant diameter (ID) (narrow platform [NP], regular platform [RP] and wide platform [WP]). Five implants were assigned to each of the nine subgroups. Implants were placed in artifi cial bone blocks with bone quality similar to D3 bone. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. T-test and Tukey’s honest signifi cant difference Post hoc were performed for data analysis. Statistical signifi cance was defi ned at P < 0.05. 
  Results: Replace select system showed signifi cantly higher primary stability compared to the Branemark system, when using the short implants for all three diameters (P ≤ 0.004). However, in medium length implants there were no signifi cant differences between the two implant systems (P ≥ 0.31). In long implants, only when the NP and RP implants were used, the Replace Select system showed signifi cantly higher primary stability compared to the Branemark system (P = 0.000). In the replace select system, long implants had a signifi cantly higher primary stability compared to medium and short length implants (P ≤ 0.003). In the NP and RP Branemark implants, short implants showed signifi cantly lower primary stability compared to medium and long implants (P ≤ 0.002). However, in WP Branemark implants, primary stability increased signifi cantly with increasing the IL from short to medium and from medium to long (P = 0.000). There were also signifi cant differences between NP and the two other wider implants in both systems (P = 0.000). 
  Conclusion: The use of tapered implants is recommended, especially, when the use of short implants is necessary. The use of RP implants is also preferred to WP implants, because thicker bone wall will remain in place when applying RP implants. Furthermore, no signifi cant difference was observed between RP and WP implants.

Source: Dental Research Journal

Full Text

واژه‌های کلیدی: Dental implants، implant geometry، osseointegration، primary stability، resonance frequency analysis
     
نوع مطالعه: پژوهشي | موضوع مقاله: پریودنتولوژی
دریافت: 1394/6/24 | پذیرش: 1394/6/24 | انتشار: 1394/6/24
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis. 1. 1390; 6 (6)

URL: http://idai.ir/article-1-3457-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 6، شماره 6 - ( پریودنتولوژی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4710