Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants.
چکیده:   (2436 مشاهده)

 Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants.
Materials and Methods: Computed tomography (CT)-–based finite element models comprising a maxillary central incisor socket and four commercially available internal-connection implants (SIN SW, 3i Certain, Nobel Replace, and ITI Standard) of comparable diameters and lengths were constructed. Biomechanical scenarios of immediate placement, immediate loading, and delayed loading protocols were simulated. Analysis of variance at the 95% confidence level was used to evaluate peak equivalent strain (EQV strain) in bone and bone-to-implant relative displacement.
Results: Loading magnitude (77.6%) and the clinical situation (15.0%) (ie, presence or absence of an extraction socket defect, condition of the bone-to-implant interface) presented the highest relative contributions to the results. Implant design contributed significantly to strains and displacements in the immediate placement protocol. Whereas a greater contribution of implant design was observed for strain values and distributions for immediately placed and immediately loaded protocols, a smaller contribution was observed in the delayed loading scenario.
Conclusion: Implant design contributes significantly to changing biomechanical scenarios for immediately placed implants. The results also suggest that avoiding implant overloading and ensuring high primary implant stability are critical in encouraging the load-bearing capability of immediately placed implants.


  Source : Journal of Oral & Maxillofacial Implant

  Full text

     
نوع مطالعه: پژوهشي | موضوع مقاله: پریودنتولوژی
دریافت: 1390/11/24 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Pessoa R S, Coelho P G, Muraru L, Marcantonio E J, Vaz L G, Sloten J V et al . Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants. . 3 2012; 6 (6)
URL: http://idai.ir/article-1-311-fa.html

Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants. . 1. 1390; 6 (6)

URL: http://idai.ir/article-1-311-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 6، شماره 6 - ( پریودنتولوژی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4714