[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: جلد 0 - ترمیمی ::
جلد 0 - ترمیمی صفحات 0-0 برگشت به فهرست نسخه ها
Cross-Compatibility of Methacrylate-Based Resin Composites and Etch-and-Rinse One-Bottle Adhesives
چکیده:   (3175 مشاهده)
Clinical Relevance

 Cross-compatibility between different combinations of methacrylate-based resin composites and etch-and-rinse one-bottle adhesives was evidenced for products from different manufacturers. This represents a desirable property of adhesives as it allows the flexibility to select different composite systems based on the specific restorative needs.

SUMMARY

 Objective: To compare dentin shear bond strength (SBS) of four combinations of light-activated one-bottle adhesives and composites to determine if cross-compatibility exists, and to determine if the use of the same manufacturer's adhesive and composite results in higher SBS than systems that combine different manufacturers' products.

 Methods: One hundred sixty human third molars were used for bonding (n=10). Specimens were treated with 37% phosphoric acid and one of four etch-and-rinse adhesives. Specimens were placed in a bonding jig, which was filled with one of four composites. Adhesives PQ1 (Ultradent), Excite (Ivoclar-Vivadent), Optibond Solo Plus (Kerr), and Single Bond (3M-ESPE) and composites Vit-l-Escence (Ultradent), Four Seasons (Ivoclar-Vivadent), Premise (Kerr), and Filtek Supreme Plus (3M-ESPE) were tested. SBS was measured at 24 hours and three months with a testing machine at a speed of 1 mm/min and expressed in MPa. A three-way analysis of variance and Tukey tests were used for data analysis.

 Results: Significant differences were evidenced among composites for each adhesive system (p<0.001) and among adhesives for each composite system (p<0.001). Optibond Solo Plus and PQ1 yielded significantly higher bond strengths than Single Bond and Excite for all composite systems (p<0.05). All combinations, with the exception of two, demonstrated a decrease in bond strength values after aging.

 Conclusions: Cross-compatibility was demonstrated, indicating that etch-and-rinse one-bottle adhesive systems can be safely used with composites from different manufacturers without a compromise to the bond strength. Moreover, even higher mean SBS values were demonstrated for selective combinations of different manufacturers' products.


  Source: Operative dentistry

  Full text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1390/11/20 | پذیرش: 1394/9/25 | انتشار: 1394/9/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sabatini C, Campillo M, Hoelz S, L. Davis E, A. Munoz C. Cross-Compatibility of Methacrylate-Based Resin Composites and Etch-and-Rinse One-Bottle Adhesives. 3 2012;
URL: http://idai.ir/article-1-258-fa.html

Cross-Compatibility of Methacrylate-Based Resin Composites and Etch-and-Rinse One-Bottle Adhesives. 1. 1390;

URL: http://idai.ir/article-1-258-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.13 seconds with 35 queries by YEKTAWEB 4710