Randomized Clinical Trial of Four Adhesion Strategies: 18-Month Results
چکیده:   (3078 مشاهده)
Clinical Relevance

 The 18-month retention rate of the two self-etch adhesives used in the present study was similar to that of two etch-and-rinse adhesives from the same manufacturer. However, the quality of enamel margins was significantly better for the two etch-and-rinse adhesives.



SUMMARY

 Statement of the Problem: With Institutional Review Board approval, 39 patients who needed restoration of noncarious cervical lesions (NCCLs) were enrolled in this study. A total of 125 NCCLs were selected and randomly assigned to four groups: 1) a three-step etch-and-rinse adhesive, Adper Scotchbond Multi-Purpose (MP, 3M ESPE, St Paul, MN, USA) 2) a two-step etch-and-rinse adhesive, Adper Single Bond Plus (SB, 3M ESPE) 3) a two-step self-etch adhesive, Adper Scotchbond SE (SE, 3M ESPE) and 4) a one-step self-etch adhesive, Adper Easy Bond (EB, 3M ESPE). A nanofilled composite resin was used for all restorations. Restorations were evaluated at six months and 18 months using modified U.S. Public Health Service (USPHS) parameters.

 Results: At six months after initial placement, 107 restorations (85.6% recall rate) were evaluated. At 18 months, 94 restorations (75.2% recall rate) were available for evaluation. The 6 mo/18 mo overall retention rates (%) were 100/90.9 for MP 100/91.7 for SB 100/90.9 for SE and 96.4/92.3 for EB with no statistical difference between any pair of groups at each recall. Sensitivity to air decreased significantly for all adhesives from the preoperative to the postoperative stage and was stable thereafter. Interfacial staining did not change statistically from baseline to six months however, interfacial staining at the enamel margins was statistically worse at 18 months than at baseline for the two self-etch adhesives EB and SE. Marginal adaptation was statistically worse at 18 months compared with baseline only for EB. This tendency was already significant at the six-month recall.

 Conclusion: Although 18-month retention was similar for the different adhesion strategies, enamel marginal deficiencies were more prevalent for the self-etch adhesives.


  Source: Operative dentistry

  Full text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1390/11/20 | پذیرش: 1394/9/25 | انتشار: 1394/9/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Perdigão J, Dutra-Corrêa M, H. C. Saraceni C, T. Ciaramicoli M, H. Kiyan V, S. Queiroz C. Randomized Clinical Trial of Four Adhesion Strategies: 18-Month Results. 3 2012;
URL: http://idai.ir/article-1-252-fa.html

Randomized Clinical Trial of Four Adhesion Strategies: 18-Month Results. 1. 1390;

URL: http://idai.ir/article-1-252-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.09 seconds with 35 queries by YEKTAWEB 4713