[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) ::
جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
Factorial analysis of variables affecting bone stress adjacent to the orthodontic anchorage mini-implant with finite element analysis
چکیده:   (1807 مشاهده)

 Introduction

  Mini-implants are now widely accepted as anchorage for orthodontic tooth movement because of the convenience of the placement procedure, their comparative low cost, and the fact that they can be immediately loaded after surgery. In this study, we incorporated a finite element approach and factorial analysis to determine the biomechanical effects of exposure length of the mini-implant, the insertion angle, and the direction of orthodontic force.

 Methods

  Twenty-seven finite element models were constructed to simulate the biomechanical response of the alveolar bone adjacent to the mini-implant. Factorial analysis was performed to investigate the comparative influence of each factor.

 Results

  The simulation results showed that the exposure length of the mini-implant had a statistically significant influence on bone stress, with a contribution of 82.35%. Increased exposure length resulted in higher bone stress adjacent to the mini-implant. Whereas all factors investigated had a statistically significant influence on cancellous bone stress, the stress values associated with cancellous bone were much less than those of cortical bone.

 Conclusions

  Increased exposure lengths resulted in higher bone stresses adjacent to the mini-implant. The percentage of contribution of the insertion angle of the mini-implant (6.03%) was also statistically significant but much less than that of the exposure length (82.35%). The direction of orthodontic force had no significant effect on cortical bone stress.


 Source: American Journal of Orthodontics & Dentofacial Orthopedics

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/3 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Factorial analysis of variables affecting bone stress adjacent to the orthodontic anchorage mini-implant with finite element analysis. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1759-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 35 queries by YEKTAWEB 4713