Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG)
چکیده:   (1673 مشاهده)

 Objectives: the aim of this study was to evaluate linear measurement accuracy of CBCT Newtom VG (Quantitative Radiology, Verona, Italy) in vitro. CBCT is dedicated to dental and Maxillofacial imaging particularly for surgical and prosthetics implant planning in dentistry. Linear measurement accuracy is important in selection of implant type , size , orientation and number of implants.

  Materials and methods: 22 anatomic landmarks in 4 dry skulls were marked by gutta – percha. 15 linear measurements were obtained using a digital caliper. These were considered as real measurements. Skulls were scanned at two settings: (a) voxel size 0.3mm (b) voxel size 0.15 mm High Resolution (HR). Radiographic distance measurement were made using the NNT viewer software in axial and coronal sections by three observers. The data were compared by mean difference, standard deviation and Intraclass Correlation Coefficient (ICC).

  Results: Mean difference of real and radiographic measurements was -0.10 0.99 mm in axial sections, -0.271.07 mm in coronal sections, +0.14 1.44mm in axial (HR) sections, 0.02 1.4mm in coronal (HR) sections. The ICC for CBCT measurements in axial sections was 0.9944, coronal sections 09941, axial (HR) sections 0.9935, coronal (HR) sections 0.9937. Statistical analysis showed high interobserver and intraobserver reliability.

 Conclusions: CBCT is reliable in linear measurement in different image planes in maxillofacial area. Voxel size has no effect on accuracy of linear measurements, so by reducing radiation dose we can have images with the same dimensional accuracy.


 Source: Dental Research Journal

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: رادیولوژی دهان، فک و صورت
دریافت: 1392/4/5 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moshefeghi M, Tavakoli M A, Tavakoli Hosseini E, Tavakoli Hosseini A, Tavakoli Hosseini I. Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG). 3 2012; 9 (9)
URL: http://idai.ir/article-1-1147-fa.html

Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG). 1. 1390; 9 (9)

URL: http://idai.ir/article-1-1147-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 9، شماره 9 - ( رادیولوژی دهان، فک و صورت 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4713