Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography
Niansong Ye , Fan Jian , Junjie Xue , Sheng Wang , Lina Liao , Wenya Huang , Xing Yang , Yang Zhou , Wenli Lai * , Jingtao Li
State Key Laboratory of Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu, China
Abstract:   (2686 Views)

 Introduction The aims of this study were to determine the accuracy of volumetric measurements of teeth in vitro by cone-beam computed tomography (CBCT) and to analyze the factors affecting their volume measurements from the CBCT data.

 Methods We used a sample of CBCT-scanned (voxel sizes: 0.125, 0.20, 0.25, 0.30, and 0.40 mm) and laser-scanned crowns (n = 40) and roots (n = 32). The Tukey test was used to assess the differences between the CBCT-scan and the laser-scan volumes.

 Results There was a statistically significant difference between the laser-scan crown volume and each voxel size of CBCT-scan crown volume (P <0.05). CBCT-scan crown volumes at 0.30 and 0.40 mm were statistically significantly distinct from those at 0.125, 0.20, and 0.25 mm (P <0.05). There was a statistically significant difference between the laser-scan root volume and each voxel size of CBCT-scan root volume (P <0.05). The laser-scan root volume at 0.40 mm was statistically significantly distinct from the volumes at 0.125 and 0.20 mm (P <0.05). The in-vitro volume measurements from the CBCT scans were larger than those of the laser scans: from 21.73% to 43.92% in the crown halves, and from 18.27% to 41.58% in the root halves at the different voxel sizes.

 Conclusions With increasing voxel sizes during scanning, the volume measurements of teeth tended to be larger. The surface surrounding artifacts might lead to larger volumes.


 Source: Journal of Orthodontics and Dentofacial Orthopedics

 Full Text

     
Type of Study: Research | Subject: Orthodontics
Received: 2012/12/3 | Published: 2012/01/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ye N, Jian F, Xue J, Wang S, Liao L, Huang W, et al . Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography. 3 2012; 1 (1 and 1)
URL: http://idai.ir/article-1-787-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 1, Issue 1 And 1 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 34 queries by YEKTAWEB 4714