| Measurement of mini-implant stability using resonance frequency analysis | 
								
								  |  | 
								
								  |  | 
								
								  |  | 
                                
								  | چکیده:       (2063 مشاهده) | 
								
								  |  Objective:     To investigate whether resonance frequency analysis (RFA) is suitable to measure orthodontic mini-implant stability. Implant size significantly affects the level of resonance frequency. Regarding the operating mode of RFA, it has to be proven whether the resonance frequency of mini-implants in bone fits the range of frequency emitted by the Osstell ISQ device.   Material and Methods:     For this purpose the SmartPegs in the Osstell ISQ device were modified to fit with the inner screw thread of orthodontic mini-implants, and 110 mini-implants were inserted into porcine pelvic bone. RFA was performed parallel and perpendicular to the run of superficial bone fibers. A suitability test, Periotest, was also performed in the same directions. Compacta thickness was measured using cone-beam computed tomography. Correlation tests and linear regression analysis were carried out between the three methods.   Results:     The RFA showed a mean Implant Stability Quotient value of 36.36 ± 2.67, and the Periotest mean value was −2.10 ± 1.17. The differences between the two directions of measurement were statistically significant (P > .001) for RFA and the Periotest. There was a high correlation between RFA and the Periotest (r  =  −0.90) and between RFA and compacta thickness (r  =  0.71). The comparison between the Periotest and compacta thickness showed a correlation coefficient of r  =  −0.64.   Conclusion:     The present results suggest that RFA is feasible as a measurement method for orthodontic mini-implant stability. As a consequence, it could be used for clinical evaluation of current stability and allow stability-related loading of mini-implants to reduce the failure rate.  
  Source: The Angel Orthodontists  Full Text | 
								
								  |  | 
								
								  | واژههای کلیدی:  Orthodontics، Skeletal anchorage، Implant stability، Resonance frequency analysis | 
								
								  |  | 
								
								  |  | 
								
								  | نوع مطالعه:  پژوهشي |
                                  موضوع مقاله: 
                                  ارتودنسی دریافت: 1392/6/31 | انتشار: 1390/10/25
 | 
                                
                                  
                                    |  | 
								
								  |  | 
								
								  |  | 
								
								  |  | 
								
								  | ارسال نظر درباره این مقاله | 
                                
                                |  | 
								
								  |  |