[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) ::
جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
An evaluation of insertion sites for mini-implants
چکیده:   (1537 مشاهده)

 Objective:

  (1) To report the thickness of the cortical bone in insertion sites commonly used for orthodontic mini-implants, (2) to assess the impact of a change in insertion angle on primary cortical bone-to-implant contact, and (3) to evaluate the risk of maxillary sinus perforation.

 Materials and Methods:  

 At autopsy, 27 human samples containing three to five adjacent teeth were excised and scanned using a table-top micro-computed tomography system. Bone thickness measurements were taken at 45° and 90° to the long the axis of the adjacent teeth, simulating a mini-implant insertion at the mid-root level.

 Results:

 In the maxilla, the overall mean cortical thickness at 90° was 0.7 mm buccally in the lateral region, 1.0 mm buccally in the anterior region, and 1.3 mm palatally. In the mandible, the mean cortical thickness was 0.7 mm buccally and 1.8 mm lingually in the anterior region 1.9 mm buccally and 2.6 mm lingually in the lateral region. Changing the insertion angle from 90° to 45° increased the cortical bone-to-implant contact by an average of 47%. Perpendicular insertion at the mid-root level only rarely interfered with the sinus, whereas apically inclined insertion increased the risk of sinus perforation.

 Conclusions:  

  Buccally and palatally in the maxilla and buccally in the anterior mandible, the thickness of the alveolar cortical bone is often less than 1 mm. In contrast, the alveolar cortical bone is frequently thicker than 2 mm laterally in the mandible. Changing the insertion angle to 45° will generally enhance implant stability but increase the risk of perforation to the maxillary sinus.


 Source: The Angel Orthodontists

 Full Text

واژه‌های کلیدی: Mini-implant، Micro-CT، Temporary anchorage، Orthodontics، Alveolar bone
     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/31 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


An evaluation of insertion sites for mini-implants. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1960-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4645