 Introduction

  The aim of this study was to determine the peri-miniscrew implant crevicular fluid receptor activator of nuclear factor-кB ligand (RANKL) and osteoprotegerin (OPG) levels around loaded and unloaded miniscrew implants at different time intervals.

 Methods

  Twenty loaded and 16 unloaded miniscrew implants were included in this study. All miniscrew implants were placed bilaterally between the maxillary second premolars and first molars as anchorage units for canine distalization. Peri-miniscrew implant crevicular fluid was taken from the mesiobuccal aspects of the loaded and unloaded miniscrew implants before loading at 24, 48, and 168 hours and on day 30 after force application. Enzyme-linked immunosorbent assay kits were used to determine RANKL and OPG levels in the peri-miniscrew implant crevicular fluid samples. Wilcoxon, Mann-Whitney U, and Spearman correlation tests were used for statistical evaluations at the P <0.05 level.

 Results

  Although the total amount of OPG was not different between the groups, the total amount of RANKL was significantly elevated in the loaded miniscrew implant group (P <0.05) at all time periods. Peri-miniscrew implant crevicular fluid volume was the highest at 48 hours in the loaded group. Also, the OPG/RANKL ratio in the peri-miniscrew implant crevicular fluid was significantly decreased in the loaded miniscrew implant group.

 Conclusions

  The OPG and RANKL levels vary around loaded and unloaded miniscrew implants as a result of force application.


 Source: American Journal of Orthodontics & Dentofacial Orthopedics

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/12 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


OPG and RANKL levels around miniscrew implants during orthodontic tooth movement. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1856-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4645