Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth
چکیده:   (1821 مشاهده)

 Objectives: Two-dimensional intraoral radiography is the most common tool for diagnosing root fractures (RFs). Cone beam CT (CBCT) is widely used to depict RFs in endodontically treated teeth. Beam hardening and other artefacts caused by gutta percha may result in an incorrect diagnosis when using CBCT only. A comparison of two CBCT machines with photostimulated phosphor (PSP) plate images enhanced with the equalization tool was carried out to detect RFs in endodontically treated teeth.

 Methods: 66 roots were collected, decoronated and treated endodontically using the same technique with gutta percha. 33 of these roots were randomly selected and fractured the 2 root fragments were glued together with 1 layer of methyl methacrylate and placed randomly in 8 prepared beef rib fragments. Large fields of view (FOVs) were acquired with one CBCT unit and small FOVs with the second CBCT unit. Periapical radiographs (using intraoral PSP plates) were also acquired. A contrast enhancement tool was used when evaluating the PSP plate images.

 Results: Small FOV images had significantly higher accuracy (area under the receiver operating characteristic curve) and sensitivity in detecting RFs than PSP plates and large FOV images. The specificity of the enhanced PSP images was higher than, although not significantly higher than, the small FOV images and was significantly higher than the large FOV images.

 Conclusions: CBCT small FOVs should be acquired for depicting RFs of endodontically treated teeth. Images obtained using PSP plates had the lowest rate of false-positive results and their use can save the patient a radiation dose.


 Source: DentoMaxilloFacial Radiology

 Full Text

واژه‌های کلیدی: cone-beam computed tomography، root fracture، diagnosis endodontics
     
نوع مطالعه: پژوهشي | موضوع مقاله: رادیولوژی دهان، فک و صورت
دریافت: 1392/5/3 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth. 1. 1390; 9 (9)

URL: http://idai.ir/article-1-1439-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 9، شماره 9 - ( رادیولوژی دهان، فک و صورت 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4710