:: دوره 9، شماره 9 - ( رادیولوژی دهان، فک و صورت 1390 ) ::
جلد 9 شماره 9 صفحات 0-0 برگشت به فهرست نسخه ها
Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth
چکیده:   (1887 مشاهده)

 Objectives: Cone beam CT (CBCT) is used widely to depict root fracture (RF) in endodontically treated teeth. Beam hardening and other artefacts due to gutta-percha may increase the time of the diagnosis and result in an incorrect diagnosis. Two CBCT machines, ProMax® (Planmeca, Helsinki, Finland) and Master 3D® (Vatech, Hwaseong, Republic of Korea), have the option of applying an artefact reduction (AR) algorithm. The aim of this study was to determine whether using an AR algorithm in two CBCT machines enhances the accuracy of detecting RFs in endodontically treated teeth.

  Methods: 66 roots were collected and decoronated. All roots were treated endodontically using the same technique with gutta-percha and zinc oxide cement. One-half of the roots were randomly selected and fractured using a nail that was tapped gently with a hammer until complete fracture resulted in two root fragments the two root fragments were glued together with one layer of methyl methacrylate. The roots were placed randomly in eight prepared beef rib fragments.

 Results: The highest accuracy was obtained when the ProMax was used without AR. The lowest accuracy was obtained with the Master 3D when used with AR. For both machines, accuracy was significantly higher without AR than with AR. Both with and without AR, the ProMax machine was significantly more accurate than the Master 3D machine. The same rank ordering was obtained for both sensitivity and specificity.

 Conclusions: For both machines, AR decreased the accuracy of RF detection in endodontically treated teeth. The highest accuracy was obtained when using the ProMax without AR.


 Source: DentoMaxilloFacial Radiology

 Full Text

واژه‌های کلیدی: cone beam computed tomography، root fracture، artefact reduction diagnosis، endodontics
     
نوع مطالعه: پژوهشي | موضوع مقاله: رادیولوژی دهان، فک و صورت
دریافت: 1392/5/1 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth. 1. 1390; 9 (9)

URL: http://idai.ir/article-1-1415-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 9، شماره 9 - ( رادیولوژی دهان، فک و صورت 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4710