[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 9, Issue 9 (1-2012) ::
3 2012, 9(9): 0-0 Back to browse issues page
A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy
C-C Chen , C-C Lin , Y-J Chen , S-W Hong , T-W Lu *
Institute of Biomedical Engineering, National Taiwan University, Taipei City, Taiwan
Abstract:   (1795 Views)

 Objectives Accurate measurement of the three-dimensional (3D) motion of the mandible in vivo is essential for relevant clinical applications. Existing techniques are either of limited accuracy or require the use of transoral devices that interfere with jaw movements. This study aimed to develop further an existing method for measuring 3D, in vivo mandibular kinematics using single-plane fluoroscopy to determine the accuracy of the method and to demonstrate its clinical applicability via measurements on a healthy subject during opening/closing and chewing movements.

 Methods The proposed method was based on the registration of single-plane fluoroscopy images and 3D low-radiation cone beam CT data. It was validated using roentgen single-plane photogrammetric analysis at static positions and during opening/closing and chewing movements.

 Results The method was found to have measurement errors of 0.1 ± 0.9 mm for all translations and 0.2° ± 0.6° for all rotations in static conditions, and of 1.0 ± 1.4 mm for all translations and 0.2° ± 0.7° for all rotations in dynamic conditions.

  Conclusions The proposed method is considered an accurate method for quantifying the 3D mandibular motion in vivo. Without relying on transoral devices, the method has advantages over existing methods, especially in the assessment of patients with missing or unstable teeth, making it useful for the research and clinical assessment of the temporomandibular joint and chewing function.


 Source: DentoMaxilloFacial Radiology

 Full Text

Keywords: temporomandibular joint, kinematics, fluoroscopy, cone beam, computed tomography, image registration
     
Type of Study: Research | Subject: Oral and Maxillofacial Radiology
Received: 2013/07/18 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Chen C, Lin C, Chen Y, Hong S, Lu T. A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy. 3 2012; 9 (9)
URL: http://idai.ir/article-1-1370-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 9 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 36 queries by YEKTAWEB 4710