[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 9, Issue 9 (1-2012) ::
3 2012, 9(9): 0-0 Back to browse issues page
The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
Arash Dabbaghi , Ali Shokraneh , Nastaran Farhadi *
Dental Implant Research Center and Department of Oral and Maxillofacial Radiology,School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
Abstract:   (1645 Views)

 Background: Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and costin comparison to computed tomography (CT) and cone beam CT. Double emulsion film usuallyused for taking tomograms requires less exposure than single emulsion film on the other hand,the latter provides more sharpness and spatial resolution. The aim of this study was to comparediagnostic accuracy of these two kinds of films in the spiral tomography.

 Materials and Methods: In an experimental study, 20 lines (10 lines anterior and 10 lines posterior to the mental foramen) were selected on two dry human mandibles and tomographic images were taken from each line with and without metal marker by single and double emulsion films. For quantitative assessment, the mandibular width and length was identified and measuredon 80obtained tomograms. Afterwards, the mandibles were sectioned on each line and theiractual width and height were measured. For each line, the data of tomograms were subtractedfrom gold standard as measurement error. These errors were divided into three groups: Greaterthan +1 mm, between +1 mm and −1 mm and less than −1 mm. Obtained data were analyzed byPearson Chi‑square test (α=0/05).

 Results: There was no significant difference between the single and double emulsion films, withand without markers in the measurement of both height and width of mandible (P > 0.05).

 Conclusion: The single emulsion film is not recommended to be used for taking the spiral tomogram.


 Source: Dental Research Journal

 Full Text

Keywords: Emulsion, tomography, X‑ray film
     
Type of Study: Research | Subject: Oral and Maxillofacial Radiology
Received: 2013/07/7 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Dabbaghi A, Shokraneh A, Farhadi N. The accuracy of single emulsion radiographic film in linear measurement of spiral tomography. 3 2012; 9 (9)
URL: http://idai.ir/article-1-1215-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 9 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 36 queries by YEKTAWEB 4710