[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: جلد 0 - ترمیمی ::
جلد 0 - ترمیمی صفحات 0-0 برگشت به فهرست نسخه ها
Effect of Powder/Liquid Ratio on Fluoride Release of Glass Ionomers
چکیده:   (1615 مشاهده)

 Objective: Evidence shows that the powder/liquid mixing ratio recommended by the manufacturers is often not respected when mixing the glass ionomer (GI) powder and liquid, yielding a GI cement with disproportionate powder/liquid ratio. Considering the confirmed effect of powder/liquid ratio on the GI properties, and more importantly, its fluoride release potential, this study aimed to assess the effect of powder/liquid ratio on fluoride release of GI cements.

  Methods: Fuji II, Fuji II LC Improved and Fuji IX GI cements were used in this experimental study. Of each material, three groups with powder 20% less than recommended, the exact recommended ratio and powder 20% more than recommended, were prepared. To assess the fluoride release potential, 45 disc-shaped specimens measuring 2×4mm were prepared (5 per each group). After fabrication, the specimens were immersed in 5 mL of distilled water. The amount of fluoride released into distilled water was measured at days 1 to 7, and also at 13, 14, 15, 28, 29, 30, 58, 59, 60, 88, 89, and 90 days, using Ion Selective Electrode (ISE). After each time of measurement, distilled water was replaced. Data were analyzed using repeated measures ANOVA. Tukey’s post hoc test was used for pairwise comparison of groups and powder/liquid mixing ratio. For pairwise comparison of time points, the Bonferroni adjustment was applied (p<0.05).

  Results: Based on the results, although the amount of fluoride released from Fuji IX was higher than Fuji II, this difference was not statistically significant (p=0.589). The lowest fluoride release was seen in Fuji II LC and this difference was statistically significant (p<0.05). Change by 20% in the powder/liquid mixing ratio in the three GI cements had no significant effect on fluoride release (p=0.650, p=0.103, p=0.082).

  Conclusion: Fluoride release from GI was time-dependent and the amount of released fluoride decreased over time. Fuji II LC resin-modified GI (RMGI) released less fluoride than Fuji II and Fuji IX. Also, 20% change in powder/liquid mixing ratio had no significant effect on fluoride release in different groups.


Source: Journal of Dental School Shahid Beheshti University of Medical Sciences

Full Text

واژه‌های کلیدی: Fluoride، Glass ionomer cement، Ion selective electrode، Powder/liquid ratio، Release pattern
     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1394/4/2 | پذیرش: 1394/4/2 | انتشار: 1394/4/2
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Effect of Powder/Liquid Ratio on Fluoride Release of Glass Ionomers. 1. 1390;

URL: http://idai.ir/article-1-2977-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.04 seconds with 37 queries by YEKTAWEB 4710