Resin-based Composite Light-cured Properties Assessed by Laboratory Standards and Simulated Clinical Conditions
چکیده:   (1749 مشاهده)

 Clinical Relevance

 The irradiation technique, used to measure mechanical properties of resin-based composites according to international standards, consistently differs from clinically simulated conditions, calling into question whether laboratory findings can be unrestrictedly applied clinically, especially at short polymerization times. The study analyzes whether degree of conversion measurements at short post-polymerization time (five minutes) are able to predict the long-term material behavior.

 SUMMARY

 The following parameters were varied: 1) irradiation technique: top and bottom polymerization according to the ISO standard, and polymerization from only the top, simulating clinical situations 2) polymerization time: 5, 10, 20, and 40 seconds 3) storage conditions: 24 hours in distilled water, thermocycling followed by storage for four weeks in artificial saliva or alcohol. Flexural strength (FS), flexural modulus (Eflexural), indentation modulus (E), Vickers hardness (HV), and degree of conversion (DC) were measured. The laboratory results were similar to those measured by mimicking clinical conditions only at high polymerization times and mild storage conditions (20 seconds and 40 seconds and storage for 24 hours in water, and 40 seconds with aging and storing in saliva). Significantly higher DC values were measured on the top than on the bottom of a 2-mm layer for all polymerization times. Overall, 5-second and 10-second irradiation times induced significantly lower DC values compared to the currently recommended polymerization times of 20 and 40 seconds at both the top and bottom of the samples. The initial DC differences as a function of irradiation time are leveled at 24 hours of storage but seem to do well in predicting long-term material behavior. A minimum irradiation time of 20 seconds is necessary clinically to achieve the best mechanical properties with modern high-intensity light emitting diode (LED) units.


 Source: Operative Dentistry

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1392/10/25 | پذیرش: 1392/10/25 | انتشار: 1392/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Resin-based Composite Light-cured Properties Assessed by Laboratory Standards and Simulated Clinical Conditions. 1. 1390;

URL: http://idai.ir/article-1-2700-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.04 seconds with 37 queries by YEKTAWEB 4710