An in vitro investigation of the effect of bevel design on the penetration and withdrawal forces of dental needles
چکیده:   (1655 مشاهده)

 Objectives

  To compare the effect on insertion and withdrawal forces using needles with a standard atraumatic bevel to those with a novel asymmetrical bevel in vitro.

 Methods

 Maximum needle penetration forces were measured using a 10N load cell mounted on an Instron universal testing machine. Forces were determined during insertion through a 0.4mm polyurethane membrane mounted at 90° (n=30 of each design), 30° (n=16 of each design) and 150° (n=16 of each design) to the needle bevel and during a 10mm insertion into a polyvinyl siloxane block mounted at 90° to the bevel (n=16 of each design). In all tests the rate of insertion was 50mm/min.

 Results

  The novel design required less force to penetrate the membrane at 30° and 150° compared to the standard design (mean forces at 30° being 0.75N and 0.98N for novel and standard designs respectively [p<0.001] and at 150° 0.52N and 0.66N respectively [p<0.001] but more force at 90° penetration tests (0.60N and 0.46N respectively [p<0.001]). The novel design required less force to insert 10mm into the polyvinyl siloxane (1.80N and 2.54N respectively [p<0.001]).

 Conclusion

  The novel design needed less force than the standard version to penetrate a thin membrane when used at 30° and 150° to the surface and to penetrate a polyvinyl siloxane block to a depth of 10mm but required more force to penetrate a thin membrane at 90°.

 Clinical significance

 Needle bevel design affects the penetration and withdrawal forces of dental needles in vitro.

 


 Source: Journal of Dentistry

 Full Text

واژه‌های کلیدی: Dental، Needle، Bevel، Penetration، In vitro
     
نوع مطالعه: پژوهشي | موضوع مقاله: سلامت دهان و جامعه نگر
دریافت: 1392/7/11 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


An in vitro investigation of the effect of bevel design on the penetration and withdrawal forces of dental needles. 1. 1390; 10 (10)

URL: http://idai.ir/article-1-2134-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 10، شماره 10 - ( سلامت دهان و جامعه نگر 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.04 seconds with 35 queries by YEKTAWEB 4710