<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>2</title>
<title_fa>1</title_fa>
<short_title>3</short_title>
<subject>Literature &amp; Humanities</subject>
<web_url>http://idai.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>9</journal_id_issn>
<journal_id_issn_online>10</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants</title_fa>
	<title></title>
	<subject_fa>پروتزهای دندانی</subject_fa>
	<subject>Prothtodontics</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;b&gt;
Background:&lt;/b&gt; Mechanical torque limiting devices (MTLDs) are necessary tools to control a peak

torque and achieving target values of screw component of dental implants. Due to probable effect

of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate

the effect of sterilization and number of use on the accuracy of friction-style mechanical torque

limiting devices (F-S MTLDs) in achieving their target torque values. &lt;div&gt; 
&lt;b&gt;Materials and Methods:&lt;/b&gt; Peak torque measurements of 15 new F-S MTLDs from three different

manufacturers (Astra Tech, BioHorizons, Dr. Idhe) were measured ten times before and after 100

steam sterilization using a digital torque gauge. To simulate the clinical situation of aging (number

of use) target torque application process was repeated 10 times after each sterilization cycle and

the peak torque values were registered. Comparison of the mean differences with target torque

in each cycle was performed using one sample t test. Considering the type of MTLDs as inter

subject comparison, One-way repeated measure ANOVA was used to evaluate the absolute values

of differences between devices of each manufacturer in each group (α = 0.05).&lt;/div&gt;&lt;div&gt;&lt;b&gt;

Results:&lt;/b&gt; The results of this study in Dr. Idhe group showed that, mean of difference values

signifi cantly differed from the target torque (P = 0.002) until 75 cycles. In Astra Tech group, also

mean of difference values with under estimation trend, showed a signifi cant difference with the

target torque (P &lt; 0.001). Mean of difference values signifi cantly differed from the target torque

with under estimation trend during all the 100 cycles in BioHorizons group (P &lt; 0.05). &lt;/div&gt;&lt;div&gt; 
&lt;b&gt;Conclusion&lt;/b&gt;: The torque output of each individual device stayed in 10% difference from target

torque values before 100 sterilization cycles, but more than 10% difference from the target torque

was seen in varying degrees during these consequent cycles.&lt;/div&gt;&lt;hr&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: left direction: ltr unicode-bidi: embed&quot;&gt;&lt;b&gt;Source:
&lt;/b&gt;Dental Research Journal &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: left direction: ltr unicode-bidi: embed&quot;&gt;&lt;a href=&quot;http://drj.mui.ac.ir/index.php/drj/article/view/1545&quot; target=&quot;_blank&quot;&gt;&lt;font color=&quot;#0000ff&quot;&gt;Full
Text&lt;/font&gt;&lt;/a&gt;&lt;/p&gt;</abstract_fa>
	<abstract></abstract>
	<keyword_fa>Calibration, dental implants, equipment failure, torque</keyword_fa>
	<keyword></keyword>
	<start_page>0</start_page>
	<end_page>0</end_page>
	<web_url>http://idai.ir/browse.php?a_code=A-10-32-3429&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Fayaz</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015722</code>
	<orcid>100319475328460015722</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Departments of Prosthodontics</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Minoo</first_name>
	<middle_name></middle_name>
	<last_name>Mahshid</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email> mdmahshid@ yahoo.com</email>
	<code>100319475328460015723</code>
	<orcid>100319475328460015723</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Departments of Prosthodontics</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Abolfazl</first_name>
	<middle_name></middle_name>
	<last_name>Saboury</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015724</code>
	<orcid>100319475328460015724</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Departments of Prosthodontics</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Jalil</first_name>
	<middle_name></middle_name>
	<last_name>Sadr</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015725</code>
	<orcid>100319475328460015725</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Departments of Prosthodontics</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Ghasem</first_name>
	<middle_name></middle_name>
	<last_name>Ansari</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460015726</code>
	<orcid>100319475328460015726</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>1 Departments Pedodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
