An evaluation of different saliva collection methods for detection of antibodies against hepatitis C virus (anti-HCV)
چکیده:   (2080 مشاهده)

 Background:  Saliva samples can be used as an alternative fluid for against hepatitis C virus (anti-HCV) detection owing to the ease of collection and excellent acceptability. This study was conducted to optimize a commercial enzyme immunoassay (EIA) to detect anti-HCV in saliva samples.

 Methods:  Ninety-six individuals donated paired serum and saliva samples that were obtained, using a commercial device (Salivette) and spitting into a sterile container. Initially, elution buffer for the Salivette samples, sample volume, incubation time and temperature, and two different anti-HCV EIAs were evaluated. Using the optimized assay, three methods for cut-off calculation were also evaluated.

 Results:  A 20-fold increase in the sample volume for both collection methods was needed. Moreover, the Radim assay was the most appropriate assay for anti-HCV detection in saliva samples, and the quality parameters were increased when a ROC curve was used to determine the cut-off value. Using this optimized assay, the sensitivities, specificities, accuracies, positive and negative predictive values were above 90% for saliva obtained using both the Salivette and spitting methods. Using this assay, discordant false-negative results were obtained for only two Salivette samples and five spitting samples. The concordance kappa was 93% for the Salivette method and 86.1% for the spitting method, demonstrating excellent performance.

 Conclusions:  Saliva samples obtained for both methods can be employed for anti-HCV detection among HCV-infected or HCV-suspected cases, but several modifications must be performed on commercial EIAs to obtain good results. Moreover, samples obtained with commercial devices are more appropriate for anti-HCV detection in saliva samples.


 Source: Journal of Oral Pathology & Medicine

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: پاتولوزی دهان، فک و صورت
دریافت: 1391/9/29 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

An evaluation of different saliva collection methods for detection of antibodies against hepatitis C virus (anti-HCV). 3 2012; 4 (4)
URL: http://idai.ir/article-1-867-fa.html

An evaluation of different saliva collection methods for detection of antibodies against hepatitis C virus (anti-HCV). 1. 1390; 4 (4)

URL: http://idai.ir/article-1-867-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 4، شماره 4 - ( مجموعه مقالات پاتولوژی فک و دهان 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.07 seconds with 35 queries by YEKTAWEB 4710