[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 9, Issue 9 (1-2012) ::
3 2012, 9(9): 0-0 Back to browse issues page
Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs
R Patcas * , G Markic , L Müller , O Ullrich , T Peltomäki , C J Kellenberger , C A Karlo
University of Zurich, Zurich, Switzerland
Abstract:   (1853 Views)

 Objectives The aim was to compare the accuracy of linear bone measurements of cone beam CT (CBCT) with multidetector CT (MDCT) and validate intraoral soft-tissue measurements in CBCT.

 Methods Comparable views of CBCT and MDCT were obtained from eight intact cadaveric heads. The anatomical positions of the gingival margin and the buccal alveolar bone ridge were determined. Image measurements (CBCT/MDCT) were performed upon multiplanar reformatted data sets and compared with the anatomical measurements the number of non-assessable sites (NASs) was evaluated.

 Results Radiological measurements were accurate with a mean difference from anatomical measurements of 0.14 mm (CBCT) and 0.23 mm (MDCT). These differences were statistically not significant, but the limits of agreement for bone measurements were broader in MDCT (−1.35 mm 1.82 mm) than in CBCT (−0.93 mm 1.21 mm). The limits of agreement for soft-tissue measurements in CBCT were smaller (−0.77 mm 1.07 mm), indicating a slightly higher accuracy. More NASs occurred in MDCT (14.5%) than in CBCT (8.3%).

 Conclusions CBCT is slightly more reliable for linear measurements than MDCT and less affected by metal artefacts. CBCT accuracy of linear intraoral soft-tissue measurements is similar to the accuracy of bone measurements.


 Source: Dentomaxillofacial Radiology Journal

 Full Text

Keywords: computed tomography, CBCT, image quality, accuracy, soft, tissue
     
Type of Study: Research | Subject: Oral and Maxillofacial Radiology
Received: 2012/12/2 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Patcas R, Markic G, Müller L, Ullrich O, Peltomäki T, Kellenberger C J et al . Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs. 3 2012; 9 (9)
URL: http://idai.ir/article-1-765-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 9 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 34 queries by YEKTAWEB 4645