[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 5، شماره 5 - ( مجموعه مقالات پروتزهای دندانی 1390 ) ::
جلد 5 شماره 5 صفحات 0-0 برگشت به فهرست نسخه ها
Evaluation of Retention of two Different Cast Post-Core Systems and Fracture Resistance of the Restored Teeth
چکیده:   (1192 مشاهده)
Statement of the Problem: The survival of pulpless teeth restored with different post and core systems is still a controversial issue.
  Purpose: This study compared the retention of two different post and core systems and also the fracture resistance of teeth restored with these systems. 
  Material and Method: Eighty endodontically treated maxillary central incisors were sectioned perpendicular to the long axis at a point 2mm incisal to the cemento-enamel junction (CEJ) and then the root canals were obturated. The restored teeth were randomly divided into two equal groups of 40. One group was restored with Nickel-Chromium (Ni-Cr) post and core system and the other group with Non-Precious Gold alloy (NPG) system. For evaluation of fracture resistance of the restored teeth, the specimens (n=20 per each group) were mounted in acrylic resin blocks and a layer of polyvinyl siloxane was applied to cover the roots. Loads were applied at an angle of 45 degrees to the long axis of the teeth and measured with a universal testing machine. The axial retention values of the studied groups (no=20) were measured on an Instron testing machine at a crosshead speed of 0.5 mm/min. Statistical analyses were performed using SPSS version 19.00 and student’s t-test (α=0.05). 
  Results: Although retention failure load for Ni-Cr system was lower than NPG system, there was no significant difference between the two systems (p= 0.7). However, fracture resistance of the teeth restored with Ni-Cr post and core system was significantly higher than NPG group (p= 0.000). 
  Conclusion: There was no significant difference between the retention of the studied post and core systems. Although significantly higher fracture thresholds were recorded for Ni-Cr post and core group, the failure loads of both systems may rarely occur clinically.

Source: Journal of Dentistry Shiraz University of Medical Sciences

Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: پروتزهای دندانی
دریافت: 1394/6/15 | پذیرش: 1394/6/15 | انتشار: 1394/6/15
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Evaluation of Retention of two Different Cast Post-Core Systems and Fracture Resistance of the Restored Teeth. 1. 1390; 5 (5)

URL: http://idai.ir/article-1-3154-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 5، شماره 5 - ( مجموعه مقالات پروتزهای دندانی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645