Influence of tooth mobility on critical stresses in all-ceramic inlay-retained fixed dental prostheses: A finite element study
چکیده:   (3329 مشاهده)
Objectives

 Inlay-retained fixed partial dentures are conservative prosthetic restorations. Their failure resistance is influenced by the stress distribution that depends on the material properties as well as the loading conditions. Finite element analysis provides the ability to estimate the loading capacity by simulating the stress distribution in all-ceramic dental restorations. The null-hypothesis of this study was that tooth mobility or tooth bearing condition significantly influences the stress distribution and therefore the failure resistance of all-ceramic inlay-retained fixed dental prostheses. Therefore, the stress distribution under different loading and bearing conditions of the teeth was analyzed using the finite element method.

Methods

 Three different bearing conditions, one fixed and two flexible were chosen to simulate tooth mobility. The flexible models were constrained with spring elements to a virtual center of rotation. In addition, loading conditions were varied.

Results

 The influence of tooth mobility on the stress distribution depended on the degree of modeled tooth mobility, as well as the loading conditions. The maximum first principal stresses differed significantly in magnitude and location depending on the modeled bearing condition and the simulated load case. The maximum difference between fixed and flexible model was more than 100%.

Significance

 Tooth mobility and occlusal loading conditions have to be considered in finite element analyses as the simulated stress distribution is strongly influenced by these factors.


  Source: Dental Materials

  Full text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ترمیمی
دریافت: 1390/11/20 | پذیرش: 1394/9/25 | انتشار: 1394/9/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Möllers K, Parkot D, Kirsten A, Güth J, Edelhoff D, Fischer H. Influence of tooth mobility on critical stresses in all-ceramic inlay-retained fixed dental prostheses: A finite element study. 3 2012;
URL: http://idai.ir/article-1-270-fa.html

Influence of tooth mobility on critical stresses in all-ceramic inlay-retained fixed dental prostheses: A finite element study. 1. 1390;

URL: http://idai.ir/article-1-270-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
جلد 0 - ترمیمی برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4714