 Objective:

  Failure of soft liners depends mostly on separation from the denture base resin therefore measurement of the bond strength is very important. The purpose of this study was to compare the tensile bond strength of two soft liners (Acropars, Molloplast-B) to denture base resin before and after thermocycling.

  Materials and Methods:

 Twenty specimens from each of the two different soft liners were processed according to the manufacturer’s instructions between two polymethyl methacrylate (PMMA) sheets. Ten specimens in each group were maintained in 37°C water for 24 hours and 10 were thermocycled (5000 cycles) among baths of 5° and 55°C. The tensile bond strength was measured using a universal testing machine at a crosshead speed of 5 mm/min. Mode of failure was determined with SEM (magnification ×30). Two-way ANOVA was used to analyze the data.

 Results:

  The mean and standard deviation of tensile bond strength of Acropars and Molloplast-B before thermocycling were 6.59±1.85 and 1.51±0.22 MPa, respectively and 5.89±1.52 and 1.37±0.18 MPa, respectively after thermocycling. There was no significant difference before and after thermocycling. Mode of failure in Acropars and Molloplast-B were adhesive and cohesive, respectivley.

  Conclusion:

  The bond strength of Acropars was significantly higher than Molloplast-B (P<0.05).


 Source: Journal of Dentistry of Tehran University of Medical Science

 Full Text

واژه‌های کلیدی: Denture Liners; Tensile Strength; Acrylic Resins; Prosthodontics
     
نوع مطالعه: پژوهشي | موضوع مقاله: پروتزهای دندانی
دریافت: 1392/9/20 | پذیرش: 1392/9/20 | انتشار: 1392/9/20
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


The Effect of Thermocycling on Tensile Bond Strength of Two Soft Liners. 1. 1390; 5 (5)

URL: http://idai.ir/article-1-2673-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 5، شماره 5 - ( مجموعه مقالات پروتزهای دندانی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4645