Measuring the Reliability of Sagittal Facial Anthropometric Measurements Under Soft Tissue Displacement Using a Modified Ruler
چکیده:   (1375 مشاهده)

 Objective:

 Despite the current use of radiography for quantifying sagittal skeletal measurements, it is an unsuitable way for screening or epidemiologic purposes. Although not fully approved, anthropometric measurements have been suggested as a substitute, and considering displacement of soft tissues, could possibly lead to more consistent results. The purpose of this study was to evaluate the reliability of anthropometric anteroposterior facial measurements under soft tissue compression using a special ruler.

 Material and Methods:

  Anthropometric measurements were done with a specifically designed sliding ruler twice on 36 adult patients with a 14 day lag between two measurements. The ruler measured the distance between the external acoustic meatus and the nasion (Na), subnasal (Sn) point and the soft tissue pogonion (Pog). The soft tissue was displaced during measurements only to the extent that the underlying hard tissue resistance was felt subjectively by each assessor. The intraclass correlation coefficient (ICC) was calculated for both inter- and intra- rater measurements using SPSS software.

 Results:

  All measurements had inter- and intrarater agreements above 0.9, with only a few parameters having lower bound confidence intervals below 0.9, but more than 0.8.

 Conclusion:

  Sagittal facial anthropometric measurements under soft tissue displacement using the specific ruler are valid and reliable and could possibly aid orthodontists in chairside craniofacial assessments.


 Source: Journal of Dentistry of Tehran University of Medical Science

 Full Text

واژه‌های کلیدی: Anthropometry; Face; Anatomy; Reproducibility of Measurements
     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/9/17 | پذیرش: 1392/9/17 | انتشار: 1392/9/17
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Measuring the Reliability of Sagittal Facial Anthropometric Measurements Under Soft Tissue Displacement Using a Modified Ruler. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-2643-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645