[صفحه اصلی ]   [Archive] [ English ]  
جستجو در پایگاه

جستجوی پیشرفته
..
نظرسنجی
مطالب کدام بخش سایت بیشتر مورد نیاز شماست؟
پرسش و پاسخ
جشنواره شهید هدایت
کلینیک تخصصی دندانپزشکی
مجله علمی
نمایشگاه کتاب
نمایشگاه مواد و تجهیزات دندانپزشکی
نیازمندیها
   
..
:: دوره 3، شماره 3 - ( مجموعه مقالات بیماری های دهان 1390 ) ::
جلد 3 شماره 3 صفحات 0-0 برگشت به فهرست نسخه ها
Influence of Test Site and Baseline Temperature on Orofacial Thermal Thresholds
چکیده:   (1566 مشاهده)

 Aims:

  To investigate thermal thresholds of selected orofacial sites, determine if there is a relationship between thermal thresholds at each site, and analyze the influence of two different baseline temperatures on thermal thresholds at the tongue tip.

 Methods:

  Thirty healthy men (mean age, 26 years) participated. Cold detection (CDT), warm detection (WDT), cold pain (CPT), and heat pain (HPT) thresholds were measured bilaterally at five orofacial sites (mentum, lower lip, cheek, forehead, and tongue tip). Relations between thermal thresholds at each test site were assessed. Thermal sensitivity of the tongue tip was compared at two different baseline temperatures (32˚C and 36˚C). One-way ANOVA, Turkey post-hoc test, paired t test and Pearson's correlation were used for statistical analyses.

 Results:

  There was a significant difference for CDT, WDT, and HPT between test sites (ANOVA, P < .001) but no significant difference for CPT (P = .634). Subjects sensitive to cooling were sensitive to warming at the mentum (r = 0.379), tongue tip (r = 0.610), and cheek (r = 0.431) but not at the other test sites. There was a strong negative correlation between CPT and HPT at all test sites. There was no significant difference for CDT and WDT at the baseline temperature of 36˚C (paired t test, P =.660), but there was a significant difference at the baseline temperature of 32˚C (P < .001). There were no significant differences between CPTs at the two different baseline temperatures (P =.773), while a significant difference existed between HPTs (P = .034).

  Conclusion:

  Thermal thresholds varied between the orofacial test sites, and baseline temperature affected thermal sensitivity of the tongue. Subjects who were relatively sensitive to cold tended to be more sensitive to heat.


 Source: Journal of Orofacial Pain

 Full Text

واژه‌های کلیدی: baseline temperature، orofacial، quantitative sensory testing، thermal thresholds، trigeminal site
     
نوع مطالعه: پژوهشي | موضوع مقاله: بیماری های دهان
دریافت: 1392/7/7 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Influence of Test Site and Baseline Temperature on Orofacial Thermal Thresholds. 1. 1390; 3 (3)

URL: http://idai.ir/article-1-2079-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 3، شماره 3 - ( مجموعه مقالات بیماری های دهان 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.07 seconds with 37 queries by YEKTAWEB 4645