جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
Retracted: Selective use of hand and forearm muscles during mini-implant insertion: a natural torquimeter
چکیده:   (1537 مشاهده)

 Objective:

 To compare maximum torque produced by different muscular groups and its influence on mini-implant insertion torque and fracture prevention. Design: A prospective study involving in vivo and in vitro laboratory experiments.

 Materials and methods:

 Eighty-seven professionals were evaluated for maximum torque produced using a screwdriver with combined action between thumb and index fingers [maximum digital torque (MDT)] and by forearm supination movement [maximum brachial torque (MBT)]. Ninety mini-implants distributed over nine different diameters and twenty commercially available mini-implants of two different diameters and trademarks were fractured to determine the fracture torque (FT). The fracture resistance index (FRI) was obtained from: FRI_MDT = FT/MDT and FRI_MBT = FT/MBT. The analysis of variance (ANOVA) and t tests were used to compare the groups.

 Results:

  MDT was smaller than MBT and both were smaller in females. FT increased for each 0·1 mm of diameter increment. FRI_MDT was greater than FRI_MBT for all diameters. FRI_MDT>1 was found when the diameter was greater than or equal to 1·5 mm. FRI_MBT>1 occurred with diameters equal or greater than 1·7 mm for females and 1·8 mm for males. The 1.5 mm and 1.6 mm diameter of commercially available and mini-implants presented FRI_MBT<1 and FRI_MDT>1.

 Conclusions:

  Digital torque was 42% smaller than brachial torque, and it was mechanically safer and biologically more compatible, allowing fracture prevention of 1·5 mm or thicker mini-implant diameter due to insertion torque limitation at 15 N/cm.


 Source: Journal of Orthodontics

 Full Text

واژه‌های کلیدی: Muscle strength، mini-implant، fracture، accident prevention
     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/17 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Retracted: Selective use of hand and forearm muscles during mini-implant insertion: a natural torquimeter. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1887-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.06 seconds with 37 queries by YEKTAWEB 4645