:: دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) ::
جلد 1 شماره 1 و 1 صفحات 0-0 برگشت به فهرست نسخه ها
Deflection and stress distribution around mini-screw implants: A finite element investigation into the effect of cortical bone thickness, force magnitude and direction
چکیده:   (1287 مشاهده)

 Objective:

  The purpose of this investigation was to quantitatively evaluate mini-screw deflection and stress distribution associated with two different cortical bone thicknesses (CBTs) under loading with two applied forces at four different angles.

 Material and methods:

 Four finite element models (ANSYS 11) of bone with mini-screws (Dentos) inserted at 90° angulation to the cortical surface were made as follows: model A: CBT 1·5 mm, load 200 g model B: CBT 2 mm, load 200 g model C: CBT 1·5 mm, load 300 g model D: CBT 2 mm, load 300 g. In each model, the loading force was applied at angulations of 70, 90, 110 and 130° to the long axis of the mini-screw. The elastic modulus of the cortical bone, cancellous bone and mini-screw were kept at 15, 1·5 and 114 GPa, respectively. The maximum equivalent stress (MES) distribution and maximum deflection (MD) at the mini-screw to bone interface was evaluated in the four models at each angulation.

 Results:

  In each model, MES and MD of the mini-screw decreased when the angulation of loading increased from 70 (MES = 2·81 MPa) to 130° (MES = 1·92 MPa). Mean MES with model A = 2·21 MPa, model B = 1·83 MPa, model C = 3·06 MPa and model D = 2·67 MPa.

 Conclusions:

  The MES and MD both decrease as the angulation of mini-screw loading increases, with increasing load differences occur in MD but the MES remains similar, whilst differences were observed in both MES and MD as CBT increased.


 Source: Journal of Orthodontics

 Full Text

واژه‌های کلیدی: Mini-screw، stability، cortical bone thickness، maximum equivalent stress
     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/17 | پذیرش: 1392/6/17 | انتشار: 1392/6/17
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Deflection and stress distribution around mini-screw implants: A finite element investigation into the effect of cortical bone thickness, force magnitude and direction. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1884-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها