Placement angle effects on the success rate of orthodontic microimplants and other factors with cone-beam computed tomography
چکیده:   (1498 مشاهده)

 Introduction

  The purpose of this study was to evaluate the effect of placement angles on the success rate of orthodontic microimplants and other factors with cone-beam computed tomography images.

 Methods

  We examined 228 orthodontic microimplants implanted into the maxillary buccal alveolar bone of 130 patients (33 men, 97 women) with malocclusion. Vertical placement angle, horizontal placement angle, root proximity, and cortical bone thickness were measured, and the correlations between these measurements and orthodontic microimplant success rates and the correlations among the measurements were evaluated.

 Results

  The overall success rate was 87.7% (200 of 228). The orthodontic microimplant success rate statistically significantly increased as root proximity (distance from the orthodontic microimplant to the root surface) increased (P <0.05), but there were no statistical significances between placement angles and success rates, and cortical bone thickness and success rate (P >0.05). Correlations between placement angles and root proximity showed no statistical significance (P >0.05), but correlations between vertical placement angle and cortical bone thickness (P <0.001) and between horizontal placement angle and cortical bone thickness (P <0.01) showed statistical significance. A statistically significant (negative) correlation was found between vertical and horizontal placement angles (P <0.001).

 Conclusions

  The success rate of orthodontic microimplants is not affected by placement angles and is more significantly affected by root proximity than by cortical bone thickness. Cortical bone thickness is affected by placement angles, but root proximity is not affected by placement angles.


 Source: American Journal of Orthodontics & Dentofacial Orthopedics

 Full Text

     
نوع مطالعه: پژوهشي | موضوع مقاله: ارتودنسی
دریافت: 1392/6/3 | انتشار: 1390/10/25
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:


Placement angle effects on the success rate of orthodontic microimplants and other factors with cone-beam computed tomography. 1. 1390; 1 (1 و 1)

URL: http://idai.ir/article-1-1758-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 1، شماره 1 و 1 - ( مجموعه مقالات ارتودنسی 1390 ) برگشت به فهرست نسخه ها
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.08 seconds with 37 queries by YEKTAWEB 4645