[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 9, Issue 9 (1-2012) ::
3 2012, 9(9): 0-0 Back to browse issues page
A comparative study of the diagnostic capabilities of 2D plain radiograph and 3D cone beam CT sialography
F J Jadu * , EWN Lam
Faculty of Dentistry, the University of Toronto, Toronto, ON, Canada
Abstract:   (1399 Views)

 Objective The aim of this study was to compare the diagnostic capabilities of two-dimensional sialography with a novel three-dimensional technique using cone beam CT (CBCT).

  Methods 47 subjects underwent parotid or submandibular gland sialography over a 2 year period using both plain imaging and CBCT. Both image sets were anonymized and independently reviewed by three certified oral and maxillofacial radiologists blinded to the clinical data. McNemar's χ2 test was used to determine differences between the two modalities for feature visualization and interpretation.

  Results CBCT outperformed plain imaging with respect to visualization of the gland parenchyma (p < 0.001) and identification of sialoliths (p = 0.02). Plain imaging outperformed CBCT for the identification of strictures (p = 0.04) however, the negative per cent agreement (“specificity”) between the two imaging modalities was 100%. Although both imaging modalities performed equally in identifying normal and abnormal sialographic examinations, CBCT demonstrated a high negative per cent agreement for normal glands and a high positive per cent agreement (“sensitivity”) for abnormal glands with inflammatory changes.

 Conclusion CBCT sialography allowed better visualization of gland parenchyma and identification of sialoliths. The high negative per cent agreement for strictures suggests that, if strictures are identified on CBCT images, then obstruction can be ruled in. Relative to plain images, the high negative per cent agreement for normal glands suggests that, if an abnormal finding is detected on CBCT images, then disease can be ruled in, and the high positive per cent agreement for glands with inflammatory changes suggests that inflammation can be ruled out if these changes are not seen on CBCT images.


 Source: DentoMaxilloFacial Radiology

 Full Text

Keywords: cone beam computed tomography, sialography, salivary gland
     
Type of Study: Research | Subject: Oral and Maxillofacial Radiology
Received: 2013/07/18 | Published: 2012/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jadu F J, Lam E. A comparative study of the diagnostic capabilities of 2D plain radiograph and 3D cone beam CT sialography. 3 2012; 9 (9)
URL: http://idai.ir/article-1-1363-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 9 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 34 queries by YEKTAWEB 4645